Potential for airborne contamination in turbulent- and unidirectional-airflow compounding aseptic isolators.

Peters GF, McKeon MR, Weiss WT

Lab Safety Corporation, Cumberland, WI, USA. valiteq@aol.com

PURPOSE: The ability of turbulent- and unidirectional-airflow compounding aseptic isolators (CAIs) to control airborne contamination during aseptic compounding of compounded sterile preparations (CSPs) was studied. METHODS: A three-phase challenge of the comparative airborne-contamination management capabilities of five CAIs was conducted using augmented, industry-standard visual tracer and discrete particle counting methods. In phase 1, a visual smoke tracer was used to conduct a standardized, comparative challenge. In phase 2, CAI operational contamination-control capabilities were measured in accordance with the International Organization for Standardization (ISO) class 5 air cleanliness conditions using a standardized CSP process qualification procedure. Alcohol drying times were also compared. In phase 3, the gross contamination clearance interval required to achieve the ISO class 5 condition after a gross contamination event was measured for each CAI. RESULTS: All four unidirectional-airflow CAIs met ISO class 5 cleanliness requirements throughout all testing phases and areas of the work zone and demonstrated alcohol drying times of 16 seconds or less. The turbulent-airflow CAI tested failed to achieve the ISO class 5 operating condition at any time during the testing and required alcohol drying times of six minutes. The unidirectional-airflow CAIs tested met the laminar-airflow workstation-equivalency requirements of chapter 797 of the United States Pharmacopeia, pharmaceutical aseptic processing standards, the industry-standard definition of a closed isolator, and the rigorous demands of pharmacy and nursing sterile compounding. CONCLUSION: The performance of four unidirectional-flow CAIs supports their use in pharmacy and nursing CSP operations, whereas the performance of one turbulent-flow CAI does not.

Published 13 March 2007 in Am J Health Syst Pharm, 64(6): 622-31.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Pharmacy Research Today. All Rights Reserved.



Pharmacy Research Today Archive:

Volume 1 (2005)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)



Pharmacy Books

Math for Meds: Dosages and Solutions

Math for Meds: Dosages and Solutions