Pharmacy Research - Drug Stores, Prescriptions, Health Care

Pharmacy Research Today is a free monthly online journal that collates and summarizes the latest research about Pharmacy, including details on drug stores, prescriptions, health care.


Pharmacy Research Today

Home

View Latest Issue

Information About Pharmacy

Books on Pharmacy

Advertising in Research Today

View Other Research Today Publications



Comparison of surface contamination with cyclophosphamide and fluorouracil using a closed-system drug transfer device versus standard preparation techniques.

Harrison BR, Peters BG, Bing MR

Department of Veterans Affairs Medical Center, St. Louis, MO, USA. harrisonbr@charter.net

PURPOSE: A comparison was conducted of the levels of surface contamination with two commonly used antineoplastic drugs, cyclophosphamide and fluorouracil, on countertops, floors, and hood surfaces in three oncology pharmacies following preparation with standard hazardous drug (HD) preparation techniques, or a closed-system drug transfer device (CSTD) in conjunction with standard HD preparation techniques, or a CSTD in conjunction with standard HD preparation techniques but prepared on a countertop outside the biological safety cabinet (BSC). METHODS: Wipe samples of the various surfaces in each pharmacy were obtained biweekly for 12 weeks (six samples) to establish a baseline. Following implementation of the CSTD, an additional six biweekly samples were collected. The CSTD was then removed, and a final six samples were collected again using standard preparation techniques. During the CSTD Phase, fluorouracil was prepared on the countertop outside the BSC. RESULTS: During the 36-week study, 342 samples were collected. A total of 8% positive fluorouracil wipe samples were found in the three pharmacies. The proportion of positive fluorouracil samples was significantly less in the CSTD Phase than in the control phases (p = 0.0002). There were 324 (95%) positive cyclophosphamide wipe samples. The median surface contamination was significantly different across the three phases (p < 0.00001). This was consistent at all sites, for both the BSC work surfaces and countertops. Contamination on floors adjacent to the BSCs was not consistently reduced. CONCLUSION: The use of a CSTD in the BSC in conjunction with standard HD preparation techniques significantly reduced cyclophosphamide surface contamination as compared to standard techniques alone. Preparation of fluorouracil outside the BSC using the CSTD did not result in significant analytically detectable contamination on the countertops.

Published 8 September 2006 in Am J Health Syst Pharm, 63(18): 1736-44.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Pharmacy Research Today. All Rights Reserved.



Pharmacy Research Today Archive:

Volume 1 (2005)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)



Pharmacy Books

The 24-Hour Pharmacist: Advice, Options, and Amazing Cures from America's Most Trusted Pharmacist

The 24-Hour Pharmacist: Advice, Options, and Amazing Cures from America's Most Trusted Pharmacist